目 录
1 概述 ··········································································..................(1)
2 技术要求 ·················································································…… (1)
2.1 仪器外观·················································································…… (1)
2.2仪器主要技术指标·····································································…… (1)
3 检定条件 ·················································································…… (1)
3.1 检定设备·················································································…… (1)
3.2 检定环境条件·········································································…… (2)
4 检定项目 ···································,···········································…… (2)
4.1 仪器外观······················,·································,························…… (2)
4.2 潮高 (水位)示值误差············,··················································…… (2)
4.3 潮高 (水位)鉴别力团·······························································…… (2)
4.4 计时示值误差······,····································································…… (2)
5 检定方法 ·················································································…… (2)
5.1 仪器外观·················································································…… (2)
5.2 潮高 (水位)示值误差·······························································…… (2)
5.3温度示值误差···········································································…… (3)
5.4 潮高鉴别力闭···········································································…… (3)
5.5计时示值误差··········································································……(4)
5.6 测试结果计算···········································································…… (4)
6 检定结果的处理和检定周期 ··················,······································…… (4)
6.1检定结果的处理········································································……(4)
6.2 检定周期·················································································…… (4)
附录A 压力验潮仪 (水位计)检定记录格式 (岸站式) ························…… (5)
附录B 压力验潮仪 (水位计)检定记录格式 (自容式) ························…… (6)
附录c 检定证书正面格式 ·······························································…… (7)
附录n 检定证书背面格式 ·······························································…… (s)
附录E 检定结果通知书正面格式 ······················································…… (9)
附录F 检定结果通知书背面格式 ······················································…… (10)
压力验潮仪检定规程
本规程适用于新制造、使用中和修理后的压力验潮仪的检定,也可用于压力水位计
的检定 。
概 述
压力验潮仪 (以下简称仪器)主要用于海洋、河流和湖泊潮汐 (水位)的测量,其
原理是由压力传感器感应水位相对变化,并由终端数字输出。有自动存储、数码管显
示、微机打印记录等功能。该仪器主要由压力传感器、测量仪表及数据传输系统组成。
压力传感器又分为弹簧式压力传感器、晶体压力传感器等。
2 技术要求
仪器外观
新出厂仪器的外壳及零部件表面的漆层、镀层应均匀光滑,刻度清晰,不得有
明显划痕、碰伤、毛刺、锈蚀和气泡等。
2.1.2 仪器各调节器应能正常调节,各部分联接要安全可靠。
2.1.3 仪器应标有名称、型号、制造厂名、返卖标志生产日期及出厂编号。
2.2 仪器主要技术指标
仪器主要技术指标列于表1